Pre-start Checks
The following pre-start checks should be done at the start of the day and every 8 hours of operation after that.
  • Check oil level.
  • Check exhaust system for leaks.
  • Check fuel system for leaks and to make sure there is adequate supply.
  • Check battery terminals for corrosion and battery for good condition.
Start and Stopping Procedures
When starting and stopping your generator, it is best to do so without loads.
  • Turn off air conditioner and other large loads before attempting to start generator.
  • If generator is diesel powered, pre-heat according to operator's manual prior to start attempt. (Quiet diesel units have automatic preheat cycle.)
  • Push and hold start switch. (Do not crank for more than 10 seconds and wait at least 30 seconds before trying again.)
  • See "Troubleshooting" section of operator's manual if set does not start.
  • Before stopping, turn off air conditioner and other heavy loads, allow set to run for 2 minutes.
  • Avoid running for long periods of time with no load or loads under 1kW. Restarting a Stalled Generator
  • Disconnect or turn off as many appliances as possible and try restarting the generator.
  • Reconnect appliances, one by one, up to a total load that does not overload generator.
Resetting a Circuit Breaker
  • If a breaker in the vehicle's main power distribution panel or on the generator trips, there is either a short circuit or too many appliances being operated at the same time.
  • Disconnect or turn off as many appliances as possible and reset the circuit breaker.
  • If the breaker does not trip, reconnect appliances, one by one, up to a total load that does not overload the generator or trip the breaker.
Cold/Hot Weather and High Altitude Operation If you travel at high altitudes or in extreme temperatures, be aware that the generator can lose power in lower-density air caused by such conditions. You may not be able to operate as many electrical devices under these conditions as you could under normal operating conditions.